Anlage 5-3-1, Delivery overview
With this system you can control your hydroponic system completely and autonomously.
The system has five dosing pumps. Since most commercially available nutrient solutions are divided into three parts in order to optimally combine the corresponding nutrients depending on the growth phase (growth, flowering, fruit), this system provides three dosing pumps for this purpose. In order to automate the more complex real-time analysis for autonomous operation, pH and EC sensors are also included in the scope of delivery. These control the concentration of the nutrient solutions as well as the pH value. The concentration of the nutrients is measured via the EC value and adjusted precisely using the three dosing pumps for the nutrient solution. Controlling the pH value allows an optimal pH level to be set using two additional dosing pumps, which add either lye or acid to the nutrient solution in doses.
Depending on the planting and the required nutrient concentrations, the dosage is preconfigured accordingly. You can obtain information about this directly from us or find it online from our database. Note: Calcium and sulfates or phosphates cannot be mixed together as they can form precipitates that clog the trickling filters of the irrigation system.
The system has a 3-stage signal tower (green, yellow, red) with warning light and buzzer. These show the operating status of the system.
You can specify the threshold values for a visual and acoustic alarm (of all eight sensors) as desired.
During regular operation, the measured values of the nutrients are shown on an LCD display. Monitor, keyboard and mouse are not required - but can of course remain connected. These are only necessary to configure the system or to display statistical data on nutrient consumption and other measured values graphically. They are also needed to control the pumps by hand. The basic operating data is displayed on an LCD display (see images below) which can also be used to calibrate analogue class sensors.
Control system, hardware consisting of:
Sensors nutrient solution
Which sensor is the right one for you?
The included standard sensors fully cover all typical use cases in the training, hobby and semi-professional fields. They are calibratable, proven, and sufficiently precise for their intended use.
The optional industrial sensors (Endress+Hauser Memosens series) are designed for operators requiring continuous, continuous operation with long calibration intervals and a digital, drift-free signal – typically commercial greenhouse operations or research facilities.
Our recommendation: If you are unsure, start with the standard. A sensor upgrade can be retrofitted at any time.
Alternative sensors can be retrofitted as needed.
| Profil | Mission | Sensor-Empfehlung |
|---|---|---|
| 🌱 Beginners / School / Hobby | Learning environment, small facility, occasional check | Standard included – you don't need anything more |
| 🏗️ Enthusiast / Semi-Professionell | Continuous operation, multiple crops, high demands | Standard + pH-Upgrade |
| 🏭 Commercial / Research | Continuous industrial operation, traceability, low-maintenance calibration | Industriesensoren (E+H Memosens) |
Endress+Hauser's Memosens sensors are designed for continuous industrial operation: digital signal, no drift losses, longer calibration intervals. In hobby or school settings, you pay for it without any equivalent value.
Environmental sensors (in greenhouse housing)
Control / actuators:
Setting up the facility
Expansion option
Using the existing environmental sensors, an additional module can be used to control the ventilation of the greenhouse as well as the artificial lighting if you are not using a greenhouse. The system is already prepared for this.
Screenshot example control center
The configuration can be designed as desired; multiple “dashboards” and multi-user operation are possible.